Hi there,
I came across an issue recently with a child primary site that had failed to replicate a number of resources from it’s parent site.
After working through some of these issues, and rectifying the replication I needed to perform a full child resync.
This is simple to do by running the following command;
- Preinst.exe /CHILDSYNC <SiteCode> ~ from the parent site
However an error was returned straight away stating that;
- Cannot connect to SQL Database
- <SiteCode> is not a known site
It turned out that this was because the account that I was using to run this did not have Site Modify permissions on the Parent Site. These permissions also need to be assigned directly to the account (not via a Security Group)
Once this was done, I re-run the command and a resync occurred.
Thanks,